Editorial Type:
Article Category: Research Article
 | 
Online Publication Date: 10 May 2012

Microimplant-based mandibular advancement therapy for the treatment of snoring and obstructive sleep apnea: a prospective study

and
Page Range: 978 – 984
DOI: 10.2319/071311-449.1
Save
Download PDF

Abstract

Objective:

To investigate the efficacy of orthodontic microimplant–based mandibular advancement therapies for the treatment of snoring and obstructive sleep apnea (OSA) in adult patients.

Materials and Methods:

Ten adult OSA patients (seven men, three women; mean age 60.00 ± 9.25 years) were each treated with two mandibular orthodontic microimplants attached to a customized reverse face mask for mandibular advancement. Pretreatment and posttreatment outcome measures of microimplant mobility, apnea-hypopnea index, snoring, respiratory movement, and Epworth sleepiness scores were evaluated after 6 months.

Results:

Highly significant reductions in the apnea-hypopnea index, snoring, and sleep variables were observed. Sixteen of the 20 (80%) microimplants were stable and showed no mobility, and four (20%) demonstrated grade 1 or 2 mobility and required removal and reinsertion of a new microimplant.

Conclusions:

Favorable reductions in sleep variables highlight the potential of microimplant-based mandibular advancement therapy as an alternative treatment modality for OSA patients who cannot tolerate continuous positive airway pressure and oral appliance therapy.

INTRODUCTION

Sleep-disordered breathing (SDB) describes a spectrum of abnormal breathing during sleep that may range from primary snoring to hypopneas to periods of obstructive sleep apnea (OSA), during which there is complete cessation of breathing.1 OSA is characterized by repetitive periods of partial or complete airway obstruction during sleep, which result in oxygen desaturation, sleep fragmentation, and frequent arousals. This common sleep disorder has been implicated in hypertension,2 stroke,3 and carotid atherosclerosis.4 Although continuous positive airway pressure (CPAP) therapy remains the gold standard treatment,5 more recently the use of oral appliances (OAs) to treat SDB has increased. OAs act primarily by mechanically advancing the mandible and tongue, thereby increasing the size of the pharyngeal lumen.6

The efficacy of OAs is variable, depending on appliance design and host factors.7 Contraindications have been found to be as high as 34% of potential patients because of dental factors, including insufficient teeth and periodontal disease.8 Side effects, although transient in nature, range from occlusal alteration to temporomandibular joint and muscular pain.9 Although adverse effects are thought to occur in the first 2 years of use, irreversible changes in jaw and dental relationships have been reported.8,10

Descriptions of SDB via prosthetic implant treatment are sparse in the literature. High cost and surgical morbidity present as limiting factors.11 Recently, we reported the use of orthodontic microimplants in the treatment of a dentate severe OSA patient.12 Two microimplants anchored to the mandible enabled skeletal anchorage for mandibular advancement (MA). A customized face mask provided extraoral anchorage, to which the microimplants were connected for titratable MA. Microimplant-based mandibular advancement (MiMA) therapy resulted in reductions in OSA symptoms and snoring.

To avoid the need for tooth anchorage of OAs and reduce the costs and morbidity associated with endosseous implants, the present prospective study investigated the use of orthodontic microimplants as an alternative method of MA. We hypothesized that microimplants can provide skeletal anchorage for MA for the treatment of snoring and OSA. The potential advantages of this novel treatment modality include the ability to treat patients with excessive missing teeth, an exaggerated gag reflex, or CPAP/OA intolerance. The added benefit of increased oral volume because of their small size and ease of placement increase the attractiveness of microimplants as a novel method of skeletal anchorage for MA.

This study furthers our investigations into the efficacy of orthodontic MiMA therapy for the treatment of snoring and OSA in adult patients.

MATERIALS AND METHODS

Subjects

Ten adult OSA patients (seven men, three women) referred by sleep physicians to a dental sleep clinic were recruited. Six of the patients had previously rejected CPAP therapy, and all patients were OA intolerant. Overnight sleep studies were used to quantify baseline sleep characteristics for all subjects. Inclusion criteria were the presence of at least two symptoms of OSA (snoring, fragmented sleep, witnessed apneas, and excessive daytime sleepiness), and evidence of OSA on sleep study with an apnea-hypopnea index (AHI) of ≥10 events/hour. Patients were excluded if there was evidence of bone disorders or regular use of sedatives. Ethical human research approval was not required. Written informed consent was obtained from all participants.

Microimplants

At T1, two orthodontic microimplants (1.6 mm diameter × 10 mm length; Absoanchor, Dentos Inc, Daegu, Korea) made of titanium alloy (titanium-aluminum-vanadium [Ti-6Al-4V]) (Figure 1) were placed in the mandible under light anesthesia (0.5 mL lidocaine). The microimplants were inserted bilaterally with the self-tapping method, with the sites of insertion based on factors such as bone quality, root proximity, and soft tissue thickness. A 1.3-mm pilot drill was used under copious saline irrigation. Each microimplant was inserted manually, and loading was delayed for at least 2 weeks.

Figure 1. Two microimplants with mushroom head for comfort (1.6 mm diameter,10 mm length).Figure 1. Two microimplants with mushroom head for comfort (1.6 mm diameter,10 mm length).Figure 1. Two microimplants with mushroom head for comfort (1.6 mm diameter,10 mm length).
Figure 1 Two microimplants with mushroom head for comfort (1.6 mm diameter,10 mm length).

Citation: The Angle Orthodontist 82, 6; 10.2319/071311-449.1

Intraoral Attachment

Two customized “shepherd's hook” attachments (Figure 2) were fabricated with 0.18-inch stainless steel wire. The attachments engaged the microimplants posteroanteriorly (Figure 3) and were extended extraorally with 60-lb fishing line (Seven Oceans, Inc, Mukilteo, WA, USA) to the midsagittal plane, where they connected to a customized reverse-pull face mask (Figure 4). An adjustable screw device on the face mask enabled titration to 70% of maximum protrusive capability. The two microimplants provided skeletal anchorage for the hook attachments to “pull” and effect MA.

Figure 2. Two customized “shepherd's hook” attachments fabricated of 0.18-inch stainless steel.Figure 2. Two customized “shepherd's hook” attachments fabricated of 0.18-inch stainless steel.Figure 2. Two customized “shepherd's hook” attachments fabricated of 0.18-inch stainless steel.
Figure 2 Two customized “shepherd's hook” attachments fabricated of 0.18-inch stainless steel.

Citation: The Angle Orthodontist 82, 6; 10.2319/071311-449.1

Figure 3. The attachments engage both microimplants in a posteroanterior direction.Figure 3. The attachments engage both microimplants in a posteroanterior direction.Figure 3. The attachments engage both microimplants in a posteroanterior direction.
Figure 3 The attachments engage both microimplants in a posteroanterior direction.

Citation: The Angle Orthodontist 82, 6; 10.2319/071311-449.1

Figure 4. The attachments extend extraorally to customized face mask.Figure 4. The attachments extend extraorally to customized face mask.Figure 4. The attachments extend extraorally to customized face mask.
Figure 4 The attachments extend extraorally to customized face mask.

Citation: The Angle Orthodontist 82, 6; 10.2319/071311-449.1

Outcome Measurements

A follow-up Sonomat sleep study (Sonomedical, Balmain, Australia) of MiMA therapy was performed at 6 months (T2). Microimplant mobility and sleep variables were recorded and defined as follows.

Microimplant mobility

Visual and tactile assessments were used to measure microimplant stability. Implants were characterized as: grade 0, no mobility; grade 1, less than 0.5 mm of lateral mobility but able to withstand force loading; or grade 2, greater than 1 mm of lateral mobility, partial/total mobility, or loss as a result of force loading.

Apnea-hypopnea index

AHI was defined as the number of apnea and hypopnea events per sleep hour. Apneas were defined as a complete cessation of breathing for a period ≥10 seconds. Hypopneas were defined as episodes >50% reduction of respiratory airflow, as determined by an increase in respiratory effort. The index time was calculated as total recording time minus total movement time, including time out of bed.

Frequency of snoring

This was expressed as total snore percentage (TS%), calculated as a percent of index time. It was defined as the amount of time spent snoring during the sleep study, excluding periods of arousals or movement.

Respiratory movement index

The respiratory movement index (RMI) was defined as the number of individual movements of a period >3 seconds that occurred per hour as the result of a respiratory event.

Epworth Sleepiness Scale

The Epworth Sleepiness Scale13 (ESS) assessed the level of daytime sleepiness.

Statistical Analysis

Statistical calculations were performed with SPSS version 17.0 statistical software (SPSS software, Chicago, Ill) for Windows. Data are presented as percentages or means ± standard deviations (SDs) for variables demonstrating normal distribution. To assess the statistical significance of treatment changes, paired Student t tests were used for parametric variables to compare baseline and treatment measures. A value of P < .05 was established as a statistically significant level.

RESULTS

The overall microimplant survival rate was 80%. Patient characteristics are outlined in Tables 1 and 2. Sixteen of the 20 microimplants (80%) were stable and showed no mobility at T2. One microimplant (patient 6), which exhibited mild inflammation and grade 1 mobility, was left in situ following oral hygiene instruction. Three microimplants (15%) demonstrated grade 2 mobility and required removal; a new microimplant was placed in all cases.

Table 1 Study Sample Characteristics at Baseline (n  =  10)
Table 1
Table 2 Individual Patient Microimplant Characteristics After MiMA Therapy (T2)
Table 2

A highly significant reduction in the AHI, from 36.8 ± 16.5 to 10.0 ± 4.5 events/hour (P  =  .005), was observed (Tables 3 and 4; Figure 5). All 10 patients had >50% reduction in AHI. Using the American Academy of Sleep Medicine classification of OSA severity, there were initially five subjects with severe OSA, four with moderate OSA, and one with mild OSA. Following MiMA therapy, there were no patients with severe OSA, one with moderate OSA, and nine with mild OSA. All five severe OSA subjects improved remarkably, with four of them (80%) having AHI <15 events/hour. The most severe OSA patient (patient 7) decreased from 63.5 to 15.7 events/hour. Four moderate OSA patients reduced their AHI to <15 events/hour and were reclassified as mild OSA.

Figure 5. Change in AHI with MiMA therapy.Figure 5. Change in AHI with MiMA therapy.Figure 5. Change in AHI with MiMA therapy.
Figure 5 Change in AHI with MiMA therapy.

Citation: The Angle Orthodontist 82, 6; 10.2319/071311-449.1

Table 3 Summary of Measurements at Baseline and After MiMA Therapy
Table 3
Table 4 Summary of Changes in Sleep Variables After MiMA Therapy (n  =  10)
Table 4

TS% values are shown in Tables 3 and 4 and Figure 6. Statistically significant reductions in snoring, from 41.6% ± 22.1% to 21.8% ± 14.4% (P  =  .005) of total sleep time, were observed. All patients reduced their snoring frequency, with five (50%) reducing their snore time by >50%. Patients 5 and 8 had an >80% reduction in snoring.

Figure 6. Change in TS% with MiMA therapy.Figure 6. Change in TS% with MiMA therapy.Figure 6. Change in TS% with MiMA therapy.
Figure 6 Change in TS% with MiMA therapy.

Citation: The Angle Orthodontist 82, 6; 10.2319/071311-449.1

Highly significant reductions in RMI (19.7 ± 18.0 versus 6.9 ± 7.3 events/hour; P  =  .005) and ESS (13.0 ± 3.3 versus 8.1 ± 3.1.; P < .0001) were observed (Tables 3 and 4). All 10 patients reduced their RMI, with eight (80%) reducing their RMI >50% during total sleep time.

Overall, initial side effects included soft tissue irritation caused by the prominence of the microimplant's mushroom-shaped head and a “morning-after” bite alteration effect. Similar to OA use, these effects were transient and resolved within 2 weeks. No dental side effects of the dentition or temporomandibular joint were seen. In contrast to OA therapy, we observed pressure sores in the area of the zygomatic pads. These areas of soft tissue compression resolved uneventfully following enlargement of the zygomatic pad area with thicker silicone material.

DISCUSSION

This prospective study introduced the novel concept of using orthodontic microimplants for the treatment of snoring and OSA. Two microimplants were placed bilaterally in the mandibles of each patient. MiMA provided an alternative to CPAP and OA therapy. Poor CPAP compliance frequently occurs as a result of side effects; hence, patients prefer OAs to CPAP therapy.14 However, Pantin et al.15 noticed that occlusal changes occurred in the first 2 years of OA use, with 7.5% of patients discontinuing treatment. Longer-term occlusal alterations have also been documented.16 Despite their increasing popularity, the compliance rate after 1 year ranges from 55% to 82% and appears to decline over time.17 This decline may be in part the result of a perceived lack of therapeutic benefit and side effects, as individual patient response to OAs can be variable and may depend on appliance design.7

Although prosthetic implants for edentulous OSA treatment have been documented,11,18 their high cost and surgical morbidity present as limiting factors. Of note, de Carlos et al.19 documented microimplant treatment of an edentulous OSA patient. To our knowledge, our study is the first to document orthodontic microimplants for the treatment of dentate and one edentulous OSA patient. At 6 months, 16 of 20 (80%) microimplants were stable, with no mobility. Poor oral hygiene and inflammation resulted in the first failure. The second failure occurred as a result of overloading, jiggling, and lateral forces from an overdenture (patient 1). Microimplant fracture during primary insertion caused the third failure. This was attributed to dense cortical bone and excessive insertion torque, despite the use of a 1.3-mm pilot drill prior to manual insertion with the self-tapping method.

In dentate patients, root proximity and cortical bone levels warrant special consideration. Studies report thicker cortical bone in the mandible, with densities dependent on the region of placement.20 Areas of cortical bone at least 1 mm thick are thought to increase microimplant stability and success.21 When evaluating dental implants, axial pull-out strength, quantifying the resistance to bone rupture in the long axis of the screw, is often used.22 However, the microimplants used for MiMA therapy are subjected to lateral loading. Additionally, torsional stress has been argued to generate a moment to the implant in the unscrewing direction.23 To minimize the counterclockwise moment, our intraoral attachments rotated freely when connected to the microimplant head.

Although the precise mechanisms for MA are unclear, imaging studies have revealed improvements in airway patency in the velopharynx, particularly in the lateral dimension.24 Dose-dependent decreases in AHI with increasing MA have been reported.25 Furthermore, a dose-dependent effect, with each 2 mm of forward positioning resulting in a 20% improvement in the number/severity of nocturnal oxygen desaturation events, has been demonstrated.26

With increasing MA, reciprocal forces are dissipated through the dentition in tooth-supported OAs, potentially causing undesirable dental side effects. In contrast, with MiMA therapy, these forces we hypothesize are skeletally supported and dissipated through the microimplants and face mask. Extraoral anchorage was provided by the face mask, with principal compressive forces noted on the zygomatic pads. During MA, we observed a rotational moment pivoting around the zygomatic pads. As the frontal pad of the face mask rotated clockwise, stringent fastening of the frontal headstraps was required to counter this rotational effect, in addition to increasing the surface area and padding on the zygomatic pads.

Importantly, the authors acknowledge the possibility that additional placement of two microimplants between the maxillary anterior teeth with interarch connectors to the mandibular microimplants for MA would negate the need for a face mask. However, only two “hidden” posterior mandibular microimplants were required when a face mask was used. Numerous clinical challenges encountered with maxillary microimplant use for MA have included thinner cortical bone and high aesthetic and soft tissue requirements and will be presented in a later publication by the authors.

Our study documented highly significant reductions in AHI, from 36.8 ± 16.5 to 10.0 ± 4.5 events/hour (P  =  .005). All patients had >50% reduction in AHI, with nine (90%) exhibiting AHI <15 events/hour and therefore being reclassified with mild OSA. Significant reductions in snoring, from 41.6% ± 22.1% to 21.8% ± 14.4% (P  =  .005) of total sleep time, were noted. However, it is noteworthy that, with the exception of patient 8, full resolution of snoring was not attained in the other nine patients. As snoring may not be directly reflected in the AHI, it is tempting to categorize low-AHI patients as low risk despite the presence of residual snoring. Increasingly, snoring is no longer thought to be a benign condition but a vibratory insult that leads to pharyngeal inflammation.27 Recent evidence associates this symptom with endothelial dysfunction as a prelude to atherosclerosis and stroke in asymptomatic mild OSA patients.4 Clinical objectives in OSA treatment should thus strive to reduce symptoms, with goals of eliminating both apneas and snoring.

Favorable improvements in RMI depict a reduction in compensatory respiratory movements and sleep fragmentation and are relevant, as decreases in slow-wave and the rapid-eye-movement sleep phase have been shown to impair function, cognition, and mood.28 The reduction in ESS scores further supports the improvements in daytime vigilance and alertness.

There are important limitations to this study. We observed only 10 patients with a diversity of dentition over a 6-month period. Longer-term studies that account for skeletal and dental changes are warranted. There was a potential for selection bias, as the referred patients had previously rejected CPAP/OA therapy and hence represented a select group of care-seeking volunteers rather than de novo OSA patients.

Given the multifactorial nature of SDB, it is prudent to note that MA poses as only one possible solution to a complex disorder. Despite recent advances in OA design and titration protocols that aim to predict success, current practice typically involves great financial expenditure without any guarantee of success. In this respect, orthodontic microimplants may, given their low cost and ease of placement, serve as a potential screening device to assess the feasibility of MA therapy. Longer-term studies in larger cohorts to assess microimplant stability and mandibular retraction forces during a complete sleep cycle are warranted.

This study introduces MiMA therapy as a novel treatment modality that can be applied clinically in patients who have insufficient teeth for OA therapy, periodontal concerns, an exaggerated gag reflex, or unresolved OA side effects. Patient selection should take into account previous OSA treatment history and local factors for successful microimplant therapy.

CONCLUSION

  • A customized titratable face mask attached to two microimplants was used to achieve mandibular advancement for the treatment of snoring and OSA.

  • The MiMA device is effective for mandibular advancement; favorable reductions in the AHI, snoring, and other sleep variables were attained.

  • MiMA therapy can provide an alternative treatment modality for adult patients who cannot tolerate CPAP and OA therapy.

REFERENCES

  • 1

    Horner, R. L.
    Pathophysiology of obstructive sleep apnea. J Cardiopulm Rehabil Prev 2008. 28:289298.

  • 2

    Lavie, P.
    ,
    P.Herer
    , and
    V.Hoffstein
    . Obstructive sleep apnoea syndrome as a risk factor for hypertension: population study.Br Med J2000. 320:479482.

  • 3

    Valham, F.
    ,
    T.Mooe
    ,
    T.Rabben
    ,
    H.Stenlund
    ,
    U.Wiklund
    , and
    K. A.Franklin
    . Increased risk of stroke in patients with coronary artery disease and sleep apnea: a 10-year follow-up.Circulation2008. 118:955960.

  • 4

    Lee, S. A.
    ,
    T. C.Amis
    ,
    K.Byth
    , et al. Heavy snoring as a cause of carotid artery atherosclerosis.Sleep2008. 31:12071213.

  • 5

    Sullivan, C. E.
    ,
    F. G.Issa
    ,
    M.Berthon-Jones
    , and
    L.Eves
    . Reversal of obstructive sleep apnoea by continuous positive airway pressure applied through the nares.Lancet1981. 1:862865.

  • 6

    Isono, S.
    ,
    J. E.Remmers
    ,
    A.Tanaka
    ,
    Y.Sho
    ,
    J.Sato
    , and
    T.Nishino
    . Anatomy of pharynx in patients with obstructive sleep apnea and in normal subjects.J Appl Physiol1997. 82:13191326.

  • 7

    Ahrens, A.
    ,
    C.McGrath
    , and
    U.Hagg
    . Subjective efficacy of oral appliance design features in the management of obstructive sleep apnea: a systematic review.Am J Orthod Dentofacial Orthop2010. 138:559576.

  • 8

    Petit, F. X.
    ,
    J. L.Pepin
    ,
    G.Bettega
    ,
    H.Sadek
    ,
    B.Raphael
    , and
    P.Levy
    . Mandibular advancement devices: rate of contraindications in 100 consecutive obstructive sleep apnea patients.Am J Respir Crit Care Med2002. 166:274278.

  • 9

    Chen, H.
    ,
    A. A.Lowe
    ,
    F. R.de Almeida
    ,
    J. A.Fleetham
    , and
    B.Wang
    . Three-dimensional computer-assisted study model analysis of long-term oral-appliance wear. Part 2. Side effects of oral appliances in obstructive sleep apnea patients.Am J Orthod Dentofacial Orthop2008. 134:408417.

  • 10

    Panula, K.
    and
    K.Keski-Nisula
    . Irreversible alteration in occlusion caused by a mandibular advancement appliance: an unexpected complication of sleep apnea treatment.Int J Adult Orthod Orthognath Surg2000. 15:192196.

  • 11

    Hoekema, A.
    ,
    F.de Vries
    ,
    K.Heydenrijk
    , and
    B.Stegenga
    . Implant-retained oral appliances: a novel treatment for edentulous patients with obstructive sleep apnea-hypopnea syndrome.Clin Oral Implants Res2007. 18:383387.

  • 12

    Ngiam, J.
    and
    H. M.Kyung
    . Microimplant mandibular advancement (MiMA) therapy for the treatment of snoring and obstructive sleep apnea (OSA).Korean J Orthod2010. 40 (
    2
    ):115126.

  • 13

    Johns, M. W.
    A new method for measuring daytime sleepiness: the Epworth sleepiness scale. Sleep 1991. 14:540545.

  • 14

    Clark, G. T.
    ,
    I.Blumenfeld
    ,
    N.Yoffe
    ,
    E.Peled
    , and
    P.Lavie
    . A crossover study comparing the efficacy of continuous positive airway pressure with anterior mandibular positioning devices on patients with obstructive sleep apnea.Chest1996. 109:14771483.

  • 15

    Pantin, C. C.
    ,
    D. R.Hillman
    , and
    M.Tennant
    . Dental side effects of an oral device to treat snoring and obstructive sleep apnea.Sleep1999. 22:237240.

  • 16

    Almeida, F. R.
    ,
    A. A.Lowe
    ,
    R.Otsuka
    ,
    S.Fastlicht
    ,
    M.Farbood
    , and
    S.Tsuiki
    . Long-term sequelae of oral appliance therapy in obstructive sleep apnea patients: part 2. Study-model analysis.Am J Orthod Dentofacial Orthop2006. 129:205213.

  • 17

    Cistulli, P. A.
    ,
    H.Gotsopoulos
    ,
    M.Marklund
    , and
    A. A.Lowe
    . Treatment of snoring and obstructive sleep apnea with mandibular repositioning appliances.Sleep Med Rev2004. 8:443457.

  • 18

    Flanagan, D.
    A removable snore reduction appliance for a mandibular edentulous patient. J Oral Implantol 2009. 35:221224.

  • 19

    de Carlos, F.
    ,
    J.Cobo
    ,
    M. P.Fernandez Mondragon
    ,
    A.Alvarez Suarez
    , and
    J.Calvo Blanco
    . Orthoimplants: an alternative treatment for SAHS?Sleep Breath2010. 14:171174.

  • 20

    Park, H. S.
    ,
    Y. J.Lee
    ,
    S. H.Jeong
    , and
    T. G.Kwon
    . Density of the alveolar and basal bones of the maxilla and the mandible.Am J Orthod Dentofacial Orthop2008. 133:3037.

  • 21

    Motoyoshi, M.
    ,
    M.Inaba
    ,
    A.Ono
    ,
    S.Ueno
    , and
    N.Shimizu
    . The effect of cortical bone thickness on the stability of orthodontic mini-implants and on the stress distribution in surrounding bone.Int J Oral Maxillofac Surg2009. 38:1318.

  • 22

    McLain, R. F.
    ,
    M. F.Fry
    ,
    T. A.Moseley
    , and
    N. A.Sharkey
    . Lumbar pedicle screw salvage: pullout testing of three different pedicle screw designs.J Spinal Disord1995. 8:6268.

  • 23

    Costa, A.
    ,
    M.Raffaini
    , and
    B.Melsen
    . Miniscrews as orthodontic anchorage: a preliminary report.Int J Adult Orthod Orthognath Surg1998. 13:201209.

  • 24

    Ryan, C. F.
    ,
    L. L.Love
    ,
    D.Peat
    ,
    J. A.Fleetham
    , and
    A. A.Lowe
    . Mandibular advancement oral appliance therapy for obstructive sleep apnoea: effect on awake calibre of the velopharynx.Thorax1999. 54:972977.

  • 25

    de Almeida, F. R.
    ,
    L. R.Bittencourt
    ,
    C. I.de Almeida
    ,
    S.Tsuiki
    ,
    A. A.Lowe
    , and
    S.Tufik
    . Effects of mandibular posture on obstructive sleep apnea severity and the temporomandibular joint in patients fitted with an oral appliance.Sleep2002. 25:507513.

  • 26

    Kato, J.
    ,
    S.Isono
    ,
    A.Tanaka
    , et al. Dose-dependent effects of mandibular advancement on pharyngeal mechanics and nocturnal oxygenation in patients with sleep-disordered breathing.Chest2000. 117:10651072.

  • 27

    Nguyen, A. T.
    ,
    V.Jobin
    ,
    R.Payne
    ,
    J.Beauregard
    ,
    N.Naor
    , and
    R. J.Kimoff
    . Laryngeal and velopharyngeal sensory impairment in obstructive sleep apnea.Sleep2005. 28:585593.

  • 28

    Bonnet, M. H.
    Effect of sleep disruption on sleep, performance, and mood. Sleep 1985. 8:1119.

Copyright: The EH Angle Education and Research Foundation, Inc.
Figure 1
Figure 1

Two microimplants with mushroom head for comfort (1.6 mm diameter,10 mm length).


Figure 2
Figure 2

Two customized “shepherd's hook” attachments fabricated of 0.18-inch stainless steel.


Figure 3
Figure 3

The attachments engage both microimplants in a posteroanterior direction.


Figure 4
Figure 4

The attachments extend extraorally to customized face mask.


Figure 5
Figure 5

Change in AHI with MiMA therapy.


Figure 6
Figure 6

Change in TS% with MiMA therapy.


Contributor Notes

Corresponding author: Prof Hee-Moon Kyung, Department of Orthodontics, School of Dentistry, Kyungpook National University, 188-1. Samduk 2 Ga, Jung Gu, Daegu, Korea 700-412 (e-mail: hmkyung@knu.ac.kr)
Received: 01 Jul 2011
Accepted: 01 Mar 2012
  • Download PDF